No. |
Item |
Data |
1 |
Inside effective size (L x W x H) |
2200 x 1000 x 1100 |
2 |
Max. load capacity |
about 5T |
3 |
Max. heating temperature |
950ºC |
4 |
Working temperature |
780~820ºC |
5 |
Heating power |
120kW |
6 |
Temperature control method |
PLC |
7 |
Temperature control precision |
±2ºC |
8 |
Temperature evenness inside |
±5ºC (in the later stage of temperature keeping) |
9 |
Furnace surface temperature rise |
35ºC+ ambient temperature |
10 |
Cooling fan motor power |
7.5kW |
11 |
Ultimate vacuity |
20Pa |
12 |
Working vacuity |
400Pa |
13 |
Vacuuming speed |
≤30min (from atmosphere to vacuity 300~900Pa |
14 |
Vacuum leakage speed |
50Pa/h |
15 |
Cooling water consumption |
10~12t/h (water pressure 0.4MPa) |